<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>pH Neutralization, pH adjustment &#187; pH Adjustment</title>
	<atom:link href="http://www.paih2o.com/tag/ph-adjustment/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.paih2o.com</link>
	<description></description>
	<lastBuildDate>Fri, 29 Jul 2011 13:12:48 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.0.5</generator>
		<item>
		<title>Center For Medical Science Chemical Kill System</title>
		<link>http://www.paih2o.com/2010/08/center-for-medical-science-chemical-kill-system/</link>
		<comments>http://www.paih2o.com/2010/08/center-for-medical-science-chemical-kill-system/#comments</comments>
		<pubDate>Tue, 17 Aug 2010 23:47:10 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[News]]></category>
		<category><![CDATA[PAI Press Releases]]></category>
		<category><![CDATA[Biodecontamination]]></category>
		<category><![CDATA[Biosafety]]></category>
		<category><![CDATA[BioSafety Lab]]></category>
		<category><![CDATA[bioterrorism]]></category>
		<category><![CDATA[BSL]]></category>
		<category><![CDATA[compliance]]></category>
		<category><![CDATA[DEP]]></category>
		<category><![CDATA[Massachusetts Department of Environmental Protection]]></category>
		<category><![CDATA[MWRA Compliance]]></category>
		<category><![CDATA[NIAID]]></category>
		<category><![CDATA[NIH]]></category>
		<category><![CDATA[pH Adjustment]]></category>
		<category><![CDATA[pH Neutralization]]></category>

		<guid isPermaLink="false">http://www.paih2o.com/?p=1413</guid>
		<description><![CDATA[For Immediate Release: August 17, 2010 Boston, MA &#8211; Practical Applications, Inc. (PAI), a leading environmental company, recently commissioned the chemical/biological decontamination system (chemical kill system) at the Center For Medical Science in Albany, NY. The Practical Applications, Inc. (PAI) Model# 1792 Chemical Kill System is designed to chemically treat waste water generated by the [...]]]></description>
			<content:encoded><![CDATA[<p>For Immediate Release: August 17, 2010</p>
<p>Boston, MA &#8211; Practical Applications, Inc. (PAI), a leading environmental company, recently commissioned the chemical/biological decontamination system (chemical kill system) at the Center For Medical Science in Albany, NY.</p>
<p><div id="attachment_1414" class="wp-caption alignleft" style="width: 310px"><a href="http://www.paih2o.com/wp-content/uploads/2010/08/CMStanks.jpg"><img src="http://www.paih2o.com/wp-content/uploads/2010/08/CMStanks-300x222.jpg" alt="Center For Medical Science Chemical Decontamination System Tanks" title="Center For Medical Science Chemical Decontamination System Tanks" width="300" height="222" class="size-medium wp-image-1414" /></a><p class="wp-caption-text">Center For Medical Science Chemical Decontamination System Tanks</p></div>The Practical Applications, Inc. (PAI) Model# 1792 Chemical Kill System is designed to chemically treat waste water generated by the Center for Medical Science (CMS) laboratory prior to sewer discharge. This model consists of two batch waste water treatment tanks with secondary containment, two mixers, four LMI reagent pumps, two chemical storage tanks with secondary containment, two ABB ORP probes, two ABB pH probes, one residual chlorine analyzer, and one ABB effluent electromagnetic flow meter. Centralized system control is provided by the main control panel mounted outside the containment area. This control panel provides all required operator interactions and the pump station for the chlorine analyzer.</p>
<p><div id="attachment_1417" class="wp-caption alignright" style="width: 190px"><a href="http://www.paih2o.com/wp-content/uploads/2010/08/CMSsystemcontrolstation.jpg"><img src="http://www.paih2o.com/wp-content/uploads/2010/08/CMSsystemcontrolstation.jpg" alt="Center For Medical Science Chemical Decontamination System Control Station" title="Center For Medical Science Chemical Decontamination System Control Station" width="180" height="360" class="size-full wp-image-1417" /></a><p class="wp-caption-text">Center For Medical Science Chemical Decontamination System Control Station</p></div>The chemical kill system is designed to treat laboratory waste water for CMS&#8217;s BSL-3 facility. The treatment uses chemical dosing to kill bacteria, viruses, and spores that may be discharged from the laboratory equipment including sinks, autoclaves, glass washers and showers. Commissioning was achieved using a modified/deactivated strain of anthrax.</p>
<p>Capable of treating up to 28,000 gallons of waste water per day, the system is intended to operate automatically and is a duplex system, utilizing two complete treatment tanks so there is always one tank online to receive waste water. A centralized main control panel provides system control components for both tanks. Operator interaction is limited to daily inspections and maintenance procedures. The system will automatically batch process and discharge biologically inactive waste water. A vacuum collection system will gravity drain the waste water into the system. The chemical kill system enters treatment mode once the batch tank reaches an operator specified level. The waste water is mixed with chemical reagents until the ORP and pH set points are reached. The system then maintains that set point for a specific dwell time before discharging the contents to the sewer. The tank discharge is monitored for flow and residual chlorine concentration. PAI has incorporated its expert knowledge into the system&#8217;s computerized control such that numerous parameters are monitored to provide safe operation and predictive maintenance.</p>
<p>PAI has been designing, building, and operating waste water treatment systems since 1994. Our systems are designed and built by operating engineers and technicians who understand that an effective system must ensure performance while remaining economical to operate and maintain.</p>
<p>Press Contact:<br />
Gary Broberg<br />
Practical Applications, Inc.<br />
Boston, MA 617-423-5639<br />
<a href="mailto:gbroberg@pai-online.com">gbroberg@pai-online.com</a></p>
<p><a href="http://paih2o.com/images/PAI-CenterForMedicalScience.pdf" title="Center for Medical Science Chemical and Biological Decontamination System Press Release PDF">Download this press release as a PDF</a></p>
]]></content:encoded>
			<wfw:commentRss>http://www.paih2o.com/2010/08/center-for-medical-science-chemical-kill-system/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Wastewater Operator Exam Prep Course</title>
		<link>http://www.paih2o.com/2009/08/wastewater-operator-exam-prep-course/</link>
		<comments>http://www.paih2o.com/2009/08/wastewater-operator-exam-prep-course/#comments</comments>
		<pubDate>Fri, 21 Aug 2009 14:21:59 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[Courses]]></category>
		<category><![CDATA[News]]></category>
		<category><![CDATA[compliance]]></category>
		<category><![CDATA[industrial water and wastewater]]></category>
		<category><![CDATA[MA Wastewater Operator]]></category>
		<category><![CDATA[Massachusetts Water Resouces Authority]]></category>
		<category><![CDATA[MWRA]]></category>
		<category><![CDATA[MWRA Compliance]]></category>
		<category><![CDATA[pH Adjustment]]></category>
		<category><![CDATA[pH Neutralization]]></category>
		<category><![CDATA[Sewer Use Discharge]]></category>
		<category><![CDATA[TCH]]></category>
		<category><![CDATA[training contact hours]]></category>
		<category><![CDATA[wastewater operator license]]></category>

		<guid isPermaLink="false">http://www.paih2o.com/blog/?p=308</guid>
		<description><![CDATA[The Practical Applications industry-leading Wastewater Operator Training Exam Prep Course will be held for 8 weeks this Autumn. Participants will be introduced to every element of the state exam, run by the New England Interstate Water Pollution Control Commission (NEIWPCC). The course is held on Thursday mornings from 8:00 to 11:00 at Practical Applications&#8217; South [...]]]></description>
			<content:encoded><![CDATA[<div id="attachment_382" class="wp-caption alignleft" style="width: 430px"><img src="http://www.paih2o.com/wp-content/uploads/2009/08/wwtof09.jpg" alt="MA Wastewater Operator Exam Training" title="MA Wastewater Operator Exam Training" width="420" height="283" class="size-full wp-image-382" /><p class="wp-caption-text">MA Wastewater Operator Exam Training</p></div>
<p>The Practical Applications industry-leading <strong>Wastewater Operator Training Exam Prep Course</strong> will be held for 8 weeks this Autumn.<br />
Participants will be introduced to every element of the state exam, run by the New England Interstate Water Pollution Control Commission (NEIWPCC).<br />
The course is held on Thursday mornings from 8:00 to 11:00 at Practical Applications&#8217; South Boston training center, starting on October 1 and concluding on November 19. The state exam will be held in multiple locations on Saturday, November 21.</p>
<p><strong>THIS COURSE IS FULL</strong></p>
]]></content:encoded>
			<wfw:commentRss>http://www.paih2o.com/2009/08/wastewater-operator-exam-prep-course/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>The David H. Koch Institute for Integrative Cancer Research At MIT Wastewater Treatment System</title>
		<link>http://www.paih2o.com/2009/08/the-david-h-koch-institute-for-integrative-cancer-research-at-mit-wastewater-treatment-system/</link>
		<comments>http://www.paih2o.com/2009/08/the-david-h-koch-institute-for-integrative-cancer-research-at-mit-wastewater-treatment-system/#comments</comments>
		<pubDate>Tue, 04 Aug 2009 01:04:09 +0000</pubDate>
		<dc:creator>admin</dc:creator>
				<category><![CDATA[News]]></category>
		<category><![CDATA[PAI Press Releases]]></category>
		<category><![CDATA[DEP]]></category>
		<category><![CDATA[industrial water and wastewater]]></category>
		<category><![CDATA[Massachusetts Water Resouces Authority]]></category>
		<category><![CDATA[MIT]]></category>
		<category><![CDATA[MWRA]]></category>
		<category><![CDATA[MWRA Compliance]]></category>
		<category><![CDATA[pH Adjustment]]></category>
		<category><![CDATA[pH Neutralization]]></category>
		<category><![CDATA[Sewer Use Discharge]]></category>
		<category><![CDATA[wastewater treatment]]></category>

		<guid isPermaLink="false">http://www.paih2o.com/blog/?p=266</guid>
		<description><![CDATA[Practical Applications, Inc. has been awarded the contract for the wastewater treatment system at the David H. Koch Institute for Integrative Cancer Research at MIT.]]></description>
			<content:encoded><![CDATA[<p>For Immediate Release: July 27, 2009</p>
<p>Boston, MA &#8211; Practical Applications, Inc. (PAI), a leading environmental company, has been awarded the contract to design and build the central wastewater treatment system for the new <a href="http://web.mit.edu/ki/" title="David H. Koch Institute for Integrative Cancer Research at MIT" target="_blank">David H. Koch Institute for Integrative Cancer Research At MIT</a>.  The system is designed to treat wastewater flows continuously at 215,000 GPD (gallons per day) with peak flows at 300 GPM (gallons per minute).<br />
The system employs <a href="http://www.paih2o.com/engineered-equipment/" title="pH Adjustment and Neutralization">pH neutralization/pH adjustment</a> to control wastewater generated from laboratory research activities. The system is designed to meet strict compliance discharge limits according to <a href="http://www.mwra.com/" title="MWRA Mass Water Resources Authority" target="blank">Massachusetts Water Resources Authority (MWRA)</a> sewer discharge regulations.<br />
<div id="attachment_265" class="wp-caption aligncenter" style="width: 426px"><img src="http://www.paih2o.com/wp-content/uploads/2009/08/1745-Elevation-View.jpg" alt="Koch Institute at MIT Wastewater Treatment System - Elevation View" title="Koch Institute at MIT Wastewater Treatment System" width="416" height="245" class="size-full wp-image-265" /><p class="wp-caption-text">Koch Institute at MIT Wastewater Treatment System - Elevation View</p></div></p>
<p>The system comprises two 2,200-Gallon treatment tanks followed by a corrosive duty pump station.  The system incorporates PAI&#8217;s proven design and safety features including our transfer free DOT chemical dispensing stations for reagents and automated alarming/reporting systems.<br />
<div id="attachment_268" class="wp-caption aligncenter" style="width: 424px"><img src="http://www.paih2o.com/wp-content/uploads/2009/08/1745-Plan-View.jpg" alt="Koch Institute at MIT Wastewater Treatment System - Plan View" title="Koch Institute at MIT Wastewater Treatment System" width="414" height="165" class="size-full wp-image-268" /><p class="wp-caption-text">Koch Institute at MIT Wastewater Treatment System - Plan View</p></div></p>
<p>PAI has been designing, building, and operating wastewater treatment systems since 1994.  Our systems are designed and built by operating engineers and technicians who understand an effective system must ensure performance while remaining economical to operate and maintain.<br />
<a href="http://paih2o.com/images/MIT-Koch-PR.pdf">Download a PDF of this press release.</a><br />
<a href="http://www.paih2o.com/ph-neutralization/" title="pH Neutralization Systems">View the MIT Koch Institute pH Neutralization System Gallery</a>.</p>
]]></content:encoded>
			<wfw:commentRss>http://www.paih2o.com/2009/08/the-david-h-koch-institute-for-integrative-cancer-research-at-mit-wastewater-treatment-system/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>
<!-- This Quick Cache file was built for (  www.paih2o.com/tag/ph-adjustment/feed/ ) in 0.32399 seconds, on Feb 5th, 2012 at 8:26 pm UTC. -->
<!-- This Quick Cache file will automatically expire ( and be re-built automatically ) on Feb 5th, 2012 at 9:26 pm UTC -->
